 +====== Attention ! ====== 
 +^  Be carefull due to a hardware change it is NOT possible to combine older versions with units produced after 01-01-2022 !!!  ^^^ 
 +|  V.10 Main\\ V.10 Extender  |  01-01-2022  |  POWER SUPPLY CHANGED TO 12 VOLT INSTEAD OF THE EARLIER USED 36 VOLT\\  MAIN V.10 and EXTENDER V.10 ARE NOT COMPATIBLE WITH OLDER VERSIONS !!!\\ Connecting a older to a newer units will damage the older unit !!!  | 
 +\\
 ^  Version  ^  Date  ^  Airence PCB info and modifications  ^ ^  Version  ^  Date  ^  Airence PCB info and modifications  ^
 |  V.1  |  06-12-2013  |  -  | |  V.1  |  06-12-2013  |  -  |
Line 18: Line 22:
 |    |    |  Airence Main and Extender remove powder coating at 15pin Sub D connector, for better ground connection  | |    |    |  Airence Main and Extender remove powder coating at 15pin Sub D connector, for better ground connection  |
 ^  ^  ^  ^ ^  ^  ^  ^
-|  V.7  |    |  Airence Main 4, 5 and 6 pcb > SMD with different ledbar drivers  |+|  V.7  |  xx-06-2016  |  Airence Main 4, 5 and 6 pcb > SMD with different ledbar drivers  |
 |    |    |  Airence Main Added Digital option  | |    |    |  Airence Main Added Digital option  |
 |    |    |  Airence 3 (Telco) > SMD with added Ring signal to Start jack  | |    |    |  Airence 3 (Telco) > SMD with added Ring signal to Start jack  |
Line 25: Line 29:
 |    |    |  __Airence V7 (Telco, Voip, Master 4, 5 and 6 pcb) not compatible with older versions due to Communication buss and Digital option. \\ You'll have to replace the complete set except Airence 6 and 7!__  | |    |    |  __Airence V7 (Telco, Voip, Master 4, 5 and 6 pcb) not compatible with older versions due to Communication buss and Digital option. \\ You'll have to replace the complete set except Airence 6 and 7!__  |
 ^  ^  ^  ^ ^  ^  ^  ^
-|  V.8  |    |  Airence 3 (Telco) > R15, R17 replaced by leaded 600mW Resistors [[https://www.d-r.nl/wiki/dokudata/faq/airence/TELCO AIRENCE MEMO-R17-R18.pdf|R17-R18 modification]]  |+|  V.8  |  xx-11-2017  |  Airence 3 (Telco) > R15, R17 replaced by leaded 600mW Resistors [[https://www.d-r.nl/wiki/dokudata/faq/airence/TELCO AIRENCE MEMO-R17-R18.pdf|R17-R18 modification]]  |
 ^  ^  ^  ^ ^  ^  ^  ^
-|  V.9  |    |  Airence 3 (Telco) > R15, R17 replaced by SMD High power  | +|  V.9  |  xx-05-2018  |  Airence 3 (Telco) > R15, R17 replaced by SMD High power  | 
 +|    |  xx-05-2018  |  Airence 10E > Mac compatible 
 +^  ^  ^  ^ 
 +|  V.10 Main\\ V.10 Extender  |  01-01-2022  |  POWER SUPPLY CHANGED TO 12 VOLT INSTEAD OF THE EARLIER USED 36 VOLT\\  MAIN V.10 and EXTENDER V.10 ARE NOT COMPATIBLE WITH OLDER VERSIONS !!!\\ Connecting a older to a newer units will damage the older unit !!!  | 
 +\\ 