-**__Question:__** Could you give us an explanation about the dip switch of C-BALANCE?\\ +^**__Question:__** Could you give us an explanation about the dip switch of C-BALANCE?^ 
-**__Answer:__** The R balance works as an N-1 and can be set with connecting the input and listening at the output.\\ +|**__Answer:__** The R balance works as an N-1 and can be set with connecting the input and listening at the output.| 
-Set the Send and Receive in the middle and the LC and HC to OFF.\\ +|Set the Send and Receive in the middle and the LC and HC to OFF.| 
-When called in adjust the potentiometer until the lowest input signal is heared.\\ +|When called in adjust the potentiometer until the lowest input signal is heared.| 
-\\ +|  | 
-The C balance should be set to the situation that the Hybrid has the lowest influence on the bus that you listen to on the mixer.\\ +|The C balance should be set to the situation that the Hybrid has the lowest influence on the bus that you listen to on the mixer.| 
-So if you offer a testing signal to a different channel and move the fader of the Hybrid the signal at the output shouldn't change.\\ +|So if you offer a testing signal to a different channel and move the fader of the Hybrid the signal at the output shouldn't change.| 
-When this is okay you can fine adjust the R balance.\\ +|When this is okay you can fine adjust the R balance.| 
-\\ +|  | 
-The easiest way is to use a 1khz 0dB test tone for both settings and a scope but it is also possible by listening and watching the VU meters.\\+|The easiest way is to use a 1khz 0dB test tone for both settings and a scope but it is also possible by listening and watching the VU meters.|
 \\ \\
 ----- -----
 \\ \\